Access Control

Build a complete access control quotation around each door

Work through the doors your customer needs and choose the readers, locking and control equipment for each one. Power supplies, cabling and installation work stay with the system, giving you a quotation that explains the complete proposed installation.

Genetec Synergis example

Include the equipment and work that complete the system

This example uses ten standard doors with HID Signo 20 readers, RTE exit, maglocks, break glass, contacts and Askari sounders. The control equipment, power supplies, licences and installation allowances are included alongside the openings.

  1. Choose the architecture

    Select the platform, gateway and control equipment. Distinguish new hardware from equipment being retained or assessed on a takeover.

  2. Build the openings

    Name each door, choose entry and exit readers, locking, request-to-exit and release equipment. Add the location and supporting installation detail.

  3. Include what makes it work

    Allow for power supplies, standby batteries, licences, cable, brackets and sundries. Keep their cost and quantity visible with the main equipment.

Northbank Exchange / AccessIllustrative workspace
10controlled doors
10HID Signo 20 readers
5MP1502 controllers
HID Signo 20 readersReader entry and request-to-exit at ten doors10
Mercury MP1502 controllersFive selected two-door controllers5
Synergis Cloud Link gatewaySelected Genetec IP gateway1
Power supplies and batteriesLocal power provision, to be checked against loads5 + 5
Maglocks and door hardwareBrackets, contacts, release, REX and Askari sounders10 sets
Reader licences and cabling10 reader licences / 1,000 m example allowanceIncluded
Existing platformCustomer-provided Security Center host and base licenceRetained
Equipment, cabling & 80 h labour
Illustrative selling prices, excluding VAT
£18,515

Review the technical decisions before you issue the quotation

Defined rules compare the equipment you have selected with the demand you have entered. You can see how the system is sized and which site facts still need confirming before the quotation is ready to issue.

Access Control / Design reviewRules and selected inputs
Door and reader capacityTen doors, ten HID Signo 20 readers and five selected MP1502 controllers.Selected architecture
Reader configurationOne reader per door and two standard reader ports per MP1502.Selected configuration
Power and standbySelected PSU and battery quantities are part of scope; load and autonomy still need design inputs.Verify design
Exit and fire interfaceDoor function, release method and any fire interface are recorded and reviewed.Site-specific
From design to customer wording

Give your customer a clear explanation of the proposed work

The selected equipment and installation work give you a detailed starting point for the customer proposal. Review the scope, assumptions, exclusions and terms so the issued quotation explains what is included and who is responsible for the remaining work.

Open a complete quotation
Illustrative scope of works

Supply and install a Genetec Synergis access-control system serving ten controlled openings at Northbank Exchange, comprising ten HID Signo 20 readers, Mercury control equipment, associated locking, Askari sounders, power supplies, licences and cabling. The customer-provided Security Center host and base platform are retained. Include configuration, commissioning and user handover.

Prepared for review before issue

The equipment and prices

Use your actual catalogue, supplier prices and commercial settings.

Prepare your catalogue

The documents that follow

Create specification, commissioning and handover documents from recorded work.

Explore the pack

The next visit

Keep the installation, field evidence and service history with the site.

Explore site records

Try ParoWorks with a job you already know

Bring your usual products and prices, then follow a familiar job through the workspace.

Start your free trial with ParoWorks